AC Gas Leak Repair Service - Split Type

Price: 10000.0

Service Description

Service Description

 

​Our process follows international HVAC standards to ensure the longevity of your compressor, especially for Inverter models.

 

  • Leak Identification:
    • Visual Inspection: Checking for oil traces on copper joints (a sign of refrigerant escape).
    • Soap Bubble Test: For accessible flare nuts and service valves.
    • Nitrogen Pressure Testing: If the leak is internal, we use high-pressure Nitrogen to pinpoint punctures in the evaporator (Indoor) or condenser (Outdoor) coils.

 

  • The Repair:
    • Brazing/Welding: Expert copper welding to seal punctured coils or U-bends.
    • Nut & Flare Replacement: Replacing worn-out brass nuts that often cause "slow leaks" over several months.

 

  • System Preparation & Charging:
    • Vacuuming: Using a specialized vacuum pump to remove all air and moisture from the lines (crucial to prevent compressor sludge).
    • Refrigerant Recharge: Filling the exact weight of R22, R32, or R410A as per the manufacturer’s specification.

 

 

Estimated Service Cost

 

  • Inspection: A visit fee applies (waived if you proceed with the repair).

 

  • Repair + Gas: Pricing depends on the AC capacity (1 Ton to 5 Ton) and the type of gas required.